Reliable Documentation for dissolved oxygen measurement: This is the inoLab® Oxi 7310 or inoLab® Oxi 7310P. A modern backlit graphic display with menu controlled user interface allows easy and intuitive operation. The mini USB-B interface provides fast data transfer to a PC. The internal memory can record up to 5000 GLP complying data including ID, date and time. The housing and the keypad are easy-to-clean. The inoLab® Oxi 7310 supports the long proven WTW galvanic sensors, CellOx® 325 and StirrOx® G. A calibration history of the 10 last calibrations allows conclusions on the state of the sensor. Calibrations versus external standards e.g. Winkler titration, are possible, too. The meter includes automatic barometric pressure and temperature compensation.
Scope of supply: Device, oxygen sensor CellOx® 325, electrolyte, abrasive foil, replacement membrane caps, universal power supply, stand, operating instructions, CD-ROM with software, USB cableScope of supply: Device, oxygen sensor CellOx® 325, electrolyte, abrasive foil, replacement membrane caps, universal power supply, stand, operating instructions, CD-ROM with software, USB cable
Hazardous Substance Data | |
GHS | ![]() ![]() |
H-Satz | H290, H315, H319 |
P-Satz | P280, P302+P352, P305+P351+P338 |
Accuracy temperature: | ±0.1 °C |
---|---|
Accuracy temperature Number: | 0.1 °C |
Battery/rechargeable battery: | 4 x 1.5 V, AA |
Concentration: | 0 ... 90 mg/l |
Concentration accuracy: | ±0.5 % of measured value |
Concentration resolution: | 0.01/0.1 |
Depth: | 230 mm |
Designation ANSI: | AA |
Dimensions (WxDxH): | 190 x 230 x 80 mm |
GHS: | GHS05, GHS07 |
Height: | 80 mm |
IP code: | IP 43 |
Interfaces: | USB-B |
Manufacturer Article Number: | 1BA301 |
Max. temperature: | 105 °C |
Max. voltage: | 240 V |
Max. voltage battery/rechargeable battery: | 1.5 V |
Min. temperature: | -5 °C |
Min. voltage: | 100 V |
No. of batteries/rechargeable batteries: | 4 |
Partial pressure: | 0 ... 1250 hPa |
Partial pressure accuracy: | ±0.5 % of measured value |
Partial pressure resolution: | 0.1/1 |
Power supply: | 100 ... 240 V, 50/60 Hz |
Power supply frequency: | 50/60 Hz |
Saturation: | 0 ... 600 % |
Saturation accuracy: | ±0.5 % of measured value |
Saturation resolution: | 0.1/1 |
Temperature: | -5 ... 105 °C |
Type: | inoLab® Oxi 7310 Set 1 |