Type 111. Resistant to steam sterilisation up to 134 °C, or in dry heat up to 180 °C. Very low adsorption (important when filtering proteinaceous solutions). Suitable for particle removal and ultracleaning of aqueous solutions, methanol, ethanol, high-grade alcohols and residue analysis of fuels and oils. The extractable content of these filters make up <1% of their weight. Other pore sizes and formats available on request.Other patterns are available on request.
Housing MBS. Minisart® High Flow PES (Polyethersulfone) syringe filters for sterile filtration, particle removal and ultra-cleaning. Covers a wide pH range. These independent ready-to-use syringe filters with PES membrane filter feature excellent flow speed and high filterable volume. The Minisart® High Flow is a syringe filter for rapid volume sterilisation with maximum user convenience. Ready-to-use units, which offer flow rates at low inlet pressures, allow for a correspondingly rapid sterile filtration.x = sterilization by gamma irradiation
White membrane with black grid, for detection of bacteria with dyed media, particle count & microscopy, individually, sterile packaged / non sterile.Hazardous Substance DataGHS symbolsSignal word according to GHSDangerH-PhrasesH228P-PhrasesP243, P234, P233, P210, P370+P380, P501
Green membrane with dark-green grid, providing optimal contrast to light-colored or transparent bacteria colonies, individually, sterile packaged / non sterile.Hazardous Substance DataGHS symbolsSignal word according to GHSDangerH-PhrasesH228P-PhrasesP230, P243, P234, P233, P210, P372, P375, P370+P380, P501UN Number3270
Gray membrane (after wetting, black) with white grid, for detection of yeasts and molds, particle count and microscopy, individually, sterile packaged / non sterile.Other types available on request.
Cellulose nitrate (cellulose ester) membrane filters, white with black grid, for colony count and sterility testing, individually, sterile packaged / non-sterile.
White membrane with green grid, for detection of bacteria with dyed media, particle count and microscopy, individually, sterile packaged / non sterile.
The very low adsorption membranes are hydrophilic, solvent-resistant (pH 3-12) and therefore suitable for the particle removal from solvents.
Type 230. Polycarbonate (PC), white, non-sterile. Ultrapure, polycarbonate membrane with especially smooth surface and fine pore distribution. Applications include COD/TOC testing, particle analysis or epifluorescence microscopy.Other patterns are available on request.
White, individually sterile packed. Resistant to steam sterilisation up to 134 °C, or in dry heat up to 180 °C. Very low adsorption (important when filtering proteinaceous solutions). Suitable for particle removal and ultracleaning of aqueous solutions, methanol, ethanol, high-grade alcohols and residue analysis of fuels and oils. The extractable content of these filters make up < 1 % of their weight. Other pore sizes and formats available on request.Other patterns are available on request.
Cellulose acetate membrane filters, white with black grid, 3 mm hydrophobic edge, for colony count and sterility testing, individually, sterile packaged.Other patterns are available on request.
White, individually sterile packed. Very low content of extractable materials. Weight constant after 60 minutes of drying at 105 °C. Suitable for residue analysis, microscopic viewing in incident or transmitted light, chemotaxis, x-ray fluorescence, spectrometry and gravimetric analysis. Autoclavable at 121 °C. Other pore sizes and formats are available on request.Other patterns are available on request.Hazardous Substance DataGHS symbolsSignal word according to GHSDangerH-PhrasesH228P-PhrasesP210, P243
For microbiological and analytical quality assurance in industry. 250 ml sterile plastic funnels reduce process time in colony and particle analysis. For use with Sartorius membrane filters and Sartorius cardboard culture plates.Note: Biosart®250 funnels can also be adapted to fit single filter holders or filtration manifolds.
White. Very low content of extractable materials. Weight constant after 60 minutes of drying at 105 °C. Suitable for residue analysis, microscopic viewing in incident or transmitted light, chemotaxis, x-ray fluorescence, spectrometry and gravimetric analysis. Autoclavable at 121 °C. Other pore sizes and formats are available on request.Other patterns are available on request.
White. For the filtration of air and gases, as well as the filtration of solvents and acids.Good chemical resistanceAutoclavableNon-sterile
White. Very low content of extractable materials. Weight constant after 60 minutes of drying at 105 °C. Suitable for residue analysis, microscopic viewing in incident or transmitted light, chemotaxis, x-ray fluorescence, spectrometry and gravimetric analysis. Autoclavable at 121 °C. Other pore sizes and formats are available on request.Hazardous Substance DataGHS symbolsSignal word according to GHSDangerH-PhrasesH228P-PhrasesP230, P243, P234, P233, P210, P372, P375, P370+P380, P501UN Number3270
Sartorius nitrocellulose membranes are available in two pore sizes, 0.22 μm and 0.45 μm. Both versions combine the advantages of high protein binding capacity with low background and high membrane stability.Easy handlingIdeal for western blotting, DNA blotting as well as dot or slot blotsOptimized for all protein blotting systemsElectrotransfer, semi-dry or or simple capillary blottingHazardous Substance DataGHS symbolsSignal word according to GHSDangerH-PhrasesH228P-PhrasesP210, P243UN Number3270
White. They are recommended for the filtration of aqueous solutions and proteins. Due to their low content of extractable substances, they are suitable for sample preparation in environmental analysis.High flow ratesLow non-specific protein adsorptionHigh resistance
Sterile, dehydrated culture media pads in petri dishes. Once they are moistened with 3.0 ml to 3.5 ml of sterile and demineralised (or distilled) water they are ready-to-use immediately. All Nutrient Pad sets are supplied with the appropriate membrane filters, which are also individually sterile packed. Alternative nutrient media are available on request.
Circular filter for ultrafiltration for sample concentration in stirring cells. The PES diaphragm offers a high flow rate.
With this dispenser you can choose between three operating modes. Operation by push button, sensor or foot switch. The dispenser is easy to transport thanks to its low weight and handy handle. The battery-operated model of the Microsart®e.motion dispenser can also be used wirelessly. This means you benefit from greater flexibility in work areas without a power connection.Capacity for up to 250 membrane filtersCleaning with standard disinfectants possibleEasy transportDimensions (WxDxH) 172 x 233 x 230 mm
For adapting Biosart® 100 monitors to the filter support of a Combisart® stainless steel bar. The adapter ensures a horizontal fit of the filtration device and minimises the risk of contamination during filtration.
Recommendations
Complies with ISO 3819 and DIN 12331Manufactured from Pyrex® borosilicate glassTall form with spoutWhite graduations and marking spotPrinted with Trace Code for downloadable batch certificateBatch certificate available to download from www.scilabware.com
Mechanically stronger than standard beakersDesigned for longer life and increased user safetyReinforced rims and spout, less prone to breakage during washing etc.Thicker walls and heavier basesManufactured from Pyrex® borosilicate glassWhite graduations and marking spot
Transparent, in different colors. With stable handle and easily readable, printed graduations on both sides. Therefore, the volume is equally visible for left- and right handers. To preserve markings, do not clean at temperatures exceeding 60 ºC.StackableFood-safe product according to regulation (EU) No. 10/2011
ISO 3819. With approximate graduations and spout. With easy-to-read scale and large labelling field for easy marking, in fired-on, highly durable white ceramic. Due to the uniformly wall thickness, it is suitable for use as a heating vessel. Glass Type I / neutral glass as per USP, EP and JP. With retrace code (Batch Identification). Certificate available via the Internet. Autoclavable.
Crystal clear. With spout and easily readable, printed red scale. To preserve markings, cleaning at no higher than 60 °C is recommended. 10 ml, 150 ml, 400 ml, 600 ml Variants in addition to ISO 7056.
Actions New
LLG-Agarose is ideal for routine separation of DNA and RNA fragments, as well as PCR products with electrophoresis. High transparency and low background of the agarose gel ensures clear and sharply defined bands.Very good dissolution and rapid gel formationHigh gel strength even at low agarose concentrationsSuitable for agarose concentrations from 0.75 up to 2 %Good separation efficiency for nucleic acid fragments between 250 bp and 23 kbFree of DNAse and RNAseHazardous Substance DataP-PhrasesP101, P102, P501
Ideal for mixing liquids. With white graduation. Acc. to DIN ISO 1773.
Dispenser box of 250 labels. These labels are produced using an extremely resistant 100 µm PE film. Due to their special surface coating they are resistant to most solvents and excellent for indoor or outdoor use. The strong adhesive, although permanent, can be removed from glass containers without leaving any trace.Trilingual signal word: German, English, French.Available in 2 sizes.
For labelling and colour coding of laboratory vessels and utensils. Strong and durable. Water resistant. Can withstand temperatures ranging from -23 °C to 121 °C. The tapes are easy to write-on and leave no residue when removed. Rolls of 12.7 m with an inner diameter of 25 mm.
Made of highly transparent Polypropylen. Functional spout to prevent dripping. With easy-to-read blue graduation for precise filling with liquids.Autoclavable at 121 °COpen handleStackableAccording to ISO 7056
High quality aluminium sample dishes, for moisture determination.
Serological pipettes from LLG are ideally suited for sterile serological and cell culture applications. Easy to read graduation scales facilitate volume measurement and dosing. All LLG serological pipettes are plugged, sterile, pyrogen-free and have an increased volume capacity through extra graduations.1 ml, 5 ml, 10 ml, 25 ml and 50 ml pipettes contain a bi-directional secondary graduation scale for precise dosingColour coded ringmark for easy volume identificationSingle packed in easy-to-open plastic/paper packagingAlso available as wide-mouth pipette (10 ml)For research and development only.
With alphanumeric coding on the edge and the bottom of each cavity. Suitable for storage in the fridge. Temperature stable between -80 °C and 100 °C.
The LLG-Timer pro can be used simultaneously as real time clock and timer. The countdown timer also runs when time is visible.Big 6-digit LCD displayDigital stopwatch (counting up)Short timer (counting down)With memory functionStopwatch and countdown up to 23 h 59 min. 59 sec.Optical and acoustic alarm when timer expiresIncl. magnet for mounting, hanging bracket and stand (fold-out)2 x 1.5 V AAA batteries not included
High-quality and stable construction made of polycarbonate. Highly transparent, lightweight, shatterproof and stackable. The Silicon O-ring and specially designed locking clip allow use without grease. Three-way stopcock provides great convenience for consistent vacuum draw, vacuum release or gas exchange e.g. inert gas. Stopcock outer diameter: 9.5 mm. Hose connection outer diam. 9.5 mm. Maximum vacuum of 1,3 mbar ( 1.33 x 10-4 MPa) for more than 72 hours, with built-in vacuum gauge. Also available in brown with UV-blocking effect for light sensitive samples.Scope of supply: Vacuum gauge, O-ring, drying agent tray, 2 x perforated sample trays (VDC-11 and VDC-21) or 3 x perforated sample trays (VDC-31 and VDC-41)