Product information "Silylation reagents - BSTFA, SILYL-991"
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.
Reagents for silylation - alkylation (methylation) - acylation are available.

N,O-bis-trimethylsilyl-trifluoroacetamide
m.w. 257.4, Bp 40°C (12mm Hg), density d20°/4° = 0.961
BSTFA: R = CF3 powerful trimethylsilyl donor with approximately the same donor strength as the non-fluorinated analogue BSA
advantage of BSTFA over BSA: greater volatility of its reaction products (particularly useful for GC of some lower boiling TMS amino acids.

BSTFA is nonpolar (less polar than MSTFA), and can be mixed with acetonitrile for improved solubility. For silylating fatty acid amides, hindered hydroxyls and other compounds, which are difficult to silylate (like secondary alcohols and amines), we recommend BSTFA + 1% trimethylchlorosilane (TMCS), available under the designation SILYL-991.
Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.
The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used immediately.
For improved volatility, better thermal stability or low limit of detection in gas chromatography prerequisite: quantitative, rapid and reproducible formation of only on derivative halogen atoms introduced by derivatisation (e.g. trifluoroacetates) allow specific detection (ECD) with the advantage of high sensitivity elution order and fragmentation patterns in MS can be influenced by a specific derivatisation.
Reagents for silylation - alkylation (methylation) - acylation are available.

N,O-bis-trimethylsilyl-trifluoroacetamide
m.w. 257.4, Bp 40°C (12mm Hg), density d20°/4° = 0.961
BSTFA: R = CF3 powerful trimethylsilyl donor with approximately the same donor strength as the non-fluorinated analogue BSA
advantage of BSTFA over BSA: greater volatility of its reaction products (particularly useful for GC of some lower boiling TMS amino acids.

BSTFA is nonpolar (less polar than MSTFA), and can be mixed with acetonitrile for improved solubility. For silylating fatty acid amides, hindered hydroxyls and other compounds, which are difficult to silylate (like secondary alcohols and amines), we recommend BSTFA + 1% trimethylchlorosilane (TMCS), available under the designation SILYL-991.
Due to their purpose, derivatisation reagents are very reactive substances. For this reason they should be stored cool and protected from moisture.
The derivatisation reagents are supplied in vials with crimp caps for easy access with a syringe. Vials with pierced sealing disks have limited stability and should be used immediately.

Hazardous Substance Data
GHS
colorpickercolorpicker
Signal word
Achtung
H-Satz
H226, H315, H319
P-Satz
P210, P280sh
UNNR
3316
SDS
Link
Capacity ml: 10
Description: BSTFA
GHS: GHS02, GHS07
Manufacturer Article Number: 701220.110
UNSPSC: 41-11-57-03
Manufacturer "Macherey-Nagel GmbH & Co. KG"

Premium Laboratory Products from Macherey-Nagel at häberle

Versatile Solutions for Research, Analytics, and Quality Assurance

As an authorized distribution partner of Macherey-Nagel, häberle offers a carefully curated range of laboratory products that deliver maximum precision and reliability for demanding applications. Whether in research institutions, testing laboratories, or industrial quality control, users benefit from innovative technologies and excellent service infrastructure.

CHROMAFIL® Filtration: Precision at Its Finest

The CHROMAFIL® syringe filters ensure efficient sample purification and particle removal prior to instrumental analysis. Various membrane materials cover a wide range of applications:

  • H-PTFE (hydrophilic PTFE): Ideal for both polar and non-polar media, such as biological samples and solvents

  • Cellulose Acetate (CA): Low protein binding, suitable for cell culture media

  • Regenerated Cellulose (RC): Chemically stable and solvent-resistant

  • Polyethersulfone (PES): High flow rate, even with viscous liquids

  • PVDF with glass fiber prefilter: Withstands high particle loads, robust for complex matrices

  • Nylon (PA), Polyester (PET), Glass Fiber (GF): Suitable for organic solvents, water, and gas filtration

Thanks to their clear PP housings and color-coded labeling, these filters integrate seamlessly into existing workflows. The CHROMAFIL® Xtra line, in particular, features specialized hydrophilic filters for ion chromatography and high-purity systems.

Rapid Tests for Efficient On-Site Analysis

To enable time-efficient chemical testing, several rapid test options are available:

  • pH indicator papers (e.g., Duotest): Accurate color-based pH measurement

  • AQUADUR® water hardness test strips: Simple determination of hardness levels in drinking and process water

  • QUANTOFIX® test strips: Semi-quantitative detection of substances such as nitrate, peroxide, or chlorine

These tests support quick decision-making in quality assurance processes and are widely used in the food industry, water treatment, and environmental analytics.

Water Analysis Instruments: Precision Meets Ease of Use

Advanced instrumentation for the determination of water components includes:

  • Photometers Advance, PF-12plus, Nanocolor VIS II and UV/VIS II: Quantitative analysis according to established standards

  • VARIO thermoblocks and round cuvette tests: Simplified handling without compromising analytical accuracy

These solutions allow laboratories of all sizes to build scalable analytical environments with consistently high data quality.

Chromatography: Optimal Separation of Complex Samples

The extensive chromatography portfolio meets the highest standards in both research and industrial analytics:

  • CHROMABOND® SPE columns: For solid-phase extraction of complex matrices

  • CHROMAFIL® filters: Sample preparation for HPLC, UHPLC, or GC

  • HPLC, UHPLC, and Flash columns, GC solutions, TLC plates: A wide selection for various separation tasks

  • Accessories such as bottles, caps, and development chambers (e.g., for TLC 10×10 cm): Fully compatible with standard systems

Special attention is given to thin-layer chromatography plates (e.g., SIL G, MN 300 cellulose), which are optimized for high-quality TLC analyses.

Bioanalytics: Efficient Nucleic Acid Isolation

The NucleoSpin®, NucleoMag®, and NucleoBond® kits offer solutions for DNA and RNA purification:

  • High yield and purity

  • Automatable protocols (e.g., with NucleoMag® technology)

  • Validated for diagnostics, molecular biology, and genomic research

These products are essential for projects requiring maximum sensitivity and reproducibility.

Why Choose häberle as Your Macherey-Nagel Partner?

Ordering through häberle comes with clear advantages:

  • Personal expert consultation from experienced product specialists

  • Full access to the complete Macherey-Nagel product range


Excellent stock availability and fast delivery times