Macherey-Nagel GmbH & Co. KG

Syringe filter CHROMAFIL®, Polytetrafluoroethylene (PTFE) ( 4003394 )

Article number: 4003394
Herstellernummer: 729008.800

on request

Colour
Connetion outlet
Manufacturer Article Number
Membrane Ø
Pore size
Type
Filter
   Available
  
   on order
Product information "Syringe filter CHROMAFIL®, Polytetrafluoroethylene (PTFE)"
The syringe filters are used for filtration of suspended matter from liquid samples and are certified for HPLC. Standard CHROMAFIL syringe filters are color coded. CHROMAFIL Xtra syringe filters are labeled for method validation and certification. All CHROMAFIL syringe filters are autoclavable (121 °C and 1.1 bar for 30 min).

A hydrophobic membrane. Ideal for filtration of non-polar liquids and gases. It is very resistant to various solvents as well as acids and bases. By flushing with alcohol, followed by water, the original hydrophobic membrane can be made more hydrophilic.
Colour: Yellow
Connetion inlet: Luer-Lock female
Connetion outlet: Minispike
Feature: Hydrophobic
Manufacturer Article Number: 729008.800
Material housing: PP
Material membrane: PTFE
Membrane Ø: 15 mm
Pore size: 0.20 µm
Sterile: No
Type: CHROMAFIL®
UNSPSC: 41104922
Manufacturer "Macherey-Nagel GmbH & Co. KG"

Premium Laboratory Products from Macherey-Nagel at häberle

Versatile Solutions for Research, Analytics, and Quality Assurance

As an authorized distribution partner of Macherey-Nagel, häberle offers a carefully curated range of laboratory products that deliver maximum precision and reliability for demanding applications. Whether in research institutions, testing laboratories, or industrial quality control, users benefit from innovative technologies and excellent service infrastructure.

CHROMAFIL® Filtration: Precision at Its Finest

The CHROMAFIL® syringe filters ensure efficient sample purification and particle removal prior to instrumental analysis. Various membrane materials cover a wide range of applications:

  • H-PTFE (hydrophilic PTFE): Ideal for both polar and non-polar media, such as biological samples and solvents

  • Cellulose Acetate (CA): Low protein binding, suitable for cell culture media

  • Regenerated Cellulose (RC): Chemically stable and solvent-resistant

  • Polyethersulfone (PES): High flow rate, even with viscous liquids

  • PVDF with glass fiber prefilter: Withstands high particle loads, robust for complex matrices

  • Nylon (PA), Polyester (PET), Glass Fiber (GF): Suitable for organic solvents, water, and gas filtration

Thanks to their clear PP housings and color-coded labeling, these filters integrate seamlessly into existing workflows. The CHROMAFIL® Xtra line, in particular, features specialized hydrophilic filters for ion chromatography and high-purity systems.

Rapid Tests for Efficient On-Site Analysis

To enable time-efficient chemical testing, several rapid test options are available:

  • pH indicator papers (e.g., Duotest): Accurate color-based pH measurement

  • AQUADUR® water hardness test strips: Simple determination of hardness levels in drinking and process water

  • QUANTOFIX® test strips: Semi-quantitative detection of substances such as nitrate, peroxide, or chlorine

These tests support quick decision-making in quality assurance processes and are widely used in the food industry, water treatment, and environmental analytics.

Water Analysis Instruments: Precision Meets Ease of Use

Advanced instrumentation for the determination of water components includes:

  • Photometers Advance, PF-12plus, Nanocolor VIS II and UV/VIS II: Quantitative analysis according to established standards

  • VARIO thermoblocks and round cuvette tests: Simplified handling without compromising analytical accuracy

These solutions allow laboratories of all sizes to build scalable analytical environments with consistently high data quality.

Chromatography: Optimal Separation of Complex Samples

The extensive chromatography portfolio meets the highest standards in both research and industrial analytics:

  • CHROMABOND® SPE columns: For solid-phase extraction of complex matrices

  • CHROMAFIL® filters: Sample preparation for HPLC, UHPLC, or GC

  • HPLC, UHPLC, and Flash columns, GC solutions, TLC plates: A wide selection for various separation tasks

  • Accessories such as bottles, caps, and development chambers (e.g., for TLC 10×10 cm): Fully compatible with standard systems

Special attention is given to thin-layer chromatography plates (e.g., SIL G, MN 300 cellulose), which are optimized for high-quality TLC analyses.

Bioanalytics: Efficient Nucleic Acid Isolation

The NucleoSpin®, NucleoMag®, and NucleoBond® kits offer solutions for DNA and RNA purification:

  • High yield and purity

  • Automatable protocols (e.g., with NucleoMag® technology)

  • Validated for diagnostics, molecular biology, and genomic research

These products are essential for projects requiring maximum sensitivity and reproducibility.

Why Choose häberle as Your Macherey-Nagel Partner?

Ordering through häberle comes with clear advantages:

  • Personal expert consultation from experienced product specialists

  • Full access to the complete Macherey-Nagel product range


Excellent stock availability and fast delivery times

Other customers also bought

Syringe filters, disposable, ReZist®PTFE
Hydrophobic PTFE-membrane, laminated with polypropylenefirst class chemical resistance opposite to common organic HPLC solventsApplication:Filtration of aggressive solutions.GF92 membrane to the prefiltration of loaded solutions.
Variants from €301.00*
Syringe filters Puradisc™, PTFE
Syringe filters are suitable for rapid sample filtration and are used in a variety of applications, such as capillary electrophoresis, protein filtration, and UV spectroscopy sample preparation. With female Luer lock inlet.For the ready-to-use filter units, only virgin raw material is used. This ensures that there is no interaction with the sample to be filtered, provided that the units are used properly. The filter units are intended for laboratory use only.Note: If syringes with a volume <10 ml are used, a pressure could be created which exceeds the max. operating pressure (700 kPa/7 bar) of the filter unit.Hydrophobic membrane. Ideal for filtration of non-polar liquids and gases.Housing made of PPOutlet male Luer coneAutoclavable at 121 °C
Variants from €166.00*