Filter
Filter
35%
Dual Use:
0
|
Filter size:
S
|
Manufacturer Article Number:
M 506-01
|
Material:
PP
|
Shelf life:
3 months
|
Thread:
GL 14
Lid with integrated ventilation openings and service life indicator. The filling of activated carbon is protected by two porous membranes made of PE. This allows an unobstructed flow of exhaust air, solvents are adsorbed by the activated carbon and only filtered air streams out.
31%
Dimensions (ØxL):
16 x 160 mm
|
Length:
160 mm
|
Manufacturer Article Number:
7600405
|
Material:
Soda-lime glass
|
UNSPSC:
41121701
|
Wall thickness:
0.6 mm
|
With beaded rim:
Yes
|
Ø:
16 mm
Test tubes with round bottom.Hydrolytic resistance: Class HGB 3 acc. to ISO 719, Type III acc. to C - USP.
Variants from €9.37*
Capillary connections:
4
|
Dual Use:
0
|
Manufacturer Article Number:
307410-PP
|
No. of blind plugs:
3
|
No. of fittings:
4 x 1,6/4 x 2,3/4 x 3,2 mm
|
Thread:
GL 45
Screw caps, with freely movable insert made of PP, for connecting capillary tubing and air valve. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Insert made of PPFittings made of PPScope of supply:Cap, fittings (PP), air valve, service life indicator, labelling field
Capillary connections:
3
|
Connection for exhaust filter:
1
|
Manufacturer Article Number:
107960
|
Material:
PTFE
|
No. of fittings:
3 x 2,3/3,2 mm
|
Thread:
S 55
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.The integrated float warns in time if the container is overfilled. Perfect for containers of opaque material, where the fill level is not visible from the outside.
Autoclavable:
Yes
|
Capillary connections:
4
|
Connection for exhaust filter:
1
|
Hose connections:
1
|
Manufacturer Article Number:
108055
|
Material:
PTFE
|
No. of fittings:
4 x 2,3 / 3,2 mm
|
No. of olives:
1
|
Thread:
S 65
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive, grounding connection
Autoclavable:
Yes
|
Capillary connections:
4
|
Connection for exhaust filter:
1
|
Manufacturer Article Number:
107928
|
Material:
PTFE
|
No. of fittings:
4 x 2,3 / 3,2 mm
|
Thread:
S 90
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive, grounding connection
Colour:
Colourless
|
Dual Use:
0
|
Manufacturer Article Number:
107168
|
Material:
PP
|
Thread:
UNF 1/4" 28G
|
UNSPSC:
41121815
For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.
Colour:
Colourless
|
Dual Use:
0
|
For ext. tubing Ø:
1.6 mm
|
Manufacturer Article Number:
107165
|
Material:
PP
|
Thread:
UNF 1/4" 28G
|
UNSPSC:
41121815
For fixing tubing in the capillary connections. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.
Colour:
Green
|
Dual Use:
0
|
Manufacturer Article Number:
317010-PP
|
Material:
PP
|
Shelf life:
6 months
|
Thread:
UNF 1/4" 28G
The air valve blocks harmful vapours and ensures safe pressure equalisation in the storage tanks. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.With filter membraneLuer-Lock connectionChange indicator
Autoclavable:
Yes
|
Capillary connections:
2
|
Connection for exhaust filter:
1
|
Dual Use:
0
|
Hose connections:
1
|
Manufacturer Article Number:
307944
|
Material:
PTFE
|
No. of blind plugs:
1
|
No. of fittings:
2 x 2,3 / 3,2 mm
|
No. of olives:
1
|
Thread:
S 60/61
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive, grounding connection
Colour:
White
|
Dual Use:
0
|
Manufacturer Article Number:
350110
|
Material:
PTFE
|
Thread:
M30x35
|
UNSPSC:
41121815
Autoclavable:
Yes
|
Capillary connections:
3
|
Connection for exhaust filter:
1
|
Manufacturer Article Number:
107936
|
Material:
PTFE
|
No. of fittings:
3 x 2,3 / 3,2 mm
|
Thread:
S 55
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, hose olive, grounding connection
Description:
HPLC Supply and waste set
|
Dual Use:
0
|
Manufacturer Article Number:
307338
Scope of supply:4 x Safety Cap III, GL458 x air valve1 x Safety Waste Cap, GL451 x Exhaust filter L, V3.0, with splash guard and change indicator, service life 12 months1 x 5 l canister, HDPE4 x Laboratory bottle DURAN, GL45, 1000 ml, clear glass, with cap and pouring ring5 x PFA-fitting, 2.3 mm OD, violet5 x PFA fitting, 1.6 mm OD, green10 x PFA fitting, 3.2 mm OD, blue10 x PFA blind plug2 x hose connectors, straight, 6 - 8 mm ID1 x hose connectors, curved, 5.0 - 11.5mm ID1 x hose connectors, angled, 9.5 - 10 mm ID
Autoclavable:
Yes
|
Capillary connections:
3
|
Connection for exhaust filter:
1
|
Manufacturer Article Number:
107915
|
Material:
PTFE
|
No. of fittings:
3 x 2,3 / 3,2 mm
|
Thread:
S 70/71
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Scope of supply:Safety Waste Cap, PFA fittings, grounding connection
Connection for exhaust filter:
1
|
Dual Use:
0
|
Manufacturer Article Number:
306482
|
Material:
PTFE
|
Thread:
S 60/61
Safe venting is optionally via SCAT exhaust air filters or direct connection to your exhaust air system. Connection GL 25.
Colour:
Black
|
Connection for exhaust filter:
1
|
Dual Use:
0
|
Manufacturer Article Number:
307971
|
Thread:
S60/61
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.NPT 3/8"Connection for exhaust air filter, 45° bevelled
Description:
HPLC Waste set 20
|
Dual Use:
0
|
Manufacturer Article Number:
307380
Scope of supply:1 x Safety Waste Cap, S60/613 x PFA fitting 2.3 mm OD3 x PFA fitting 2.3 mm OD3 x PFA fitting 3.2 mm OD3 x PP tube connector 5.0 - 11.5mm ID1 x GL14 connection for exhaust filter1 x canister, S60/61, 5 l, HDPE, UN-X1 x exhaust filter M, with splash guard and change indicator
Capillary connections:
3
|
Connection for exhaust filter:
1
|
Manufacturer Article Number:
108200
|
Material:
PTFE
|
No. of fittings:
3 x 2,3/3,2 mm
|
Thread:
S 55
|
UNSPSC:
41-12-18-14
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.Electronic level control with floater and signal cable for connecting with electronic signal boxes.
Description:
HPLC starter kit IV
|
Dual Use:
0
|
Manufacturer Article Number:
399203-PP
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with PP fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap IV, GL 45, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator16 x PP fitting 1.6 mm OD16 x PP fitting 2.3 mm OD16 x PP fitting 3.2 mm OD12 x PP blind plug4 x labelling field
Manufacturer Article Number:
761124.40
|
Type:
for 4 and 4.6 mm i.d.
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Colour:
Blue/white
|
Connection for exhaust filter:
1
|
Dual Use:
0
|
Manufacturer Article Number:
307970
|
Thread:
S60/61
For the safe withdrawal of solvents. Screw caps, with freely movable insert made of PTFE, with PFA fittings for capillaries, hose olives for tubes with 5.0 - 11.5 mm inner diameter and a connection for exhaust air filter. Please order your exhaust filter separately.NPT 3/8"Connection for exhaust air filter, 45° bevelled
Description:
HPLC starter kit III
|
Dual Use:
0
|
Manufacturer Article Number:
399202-PP
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with PP fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:4 x Safety Cap III, GL 45, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator12 x PP fitting 1.6 mm OD12 x PP fitting 2.3 mm OD12 x PP fitting 3.2 mm OD8 x PP blind plug4 x labelling field
Bore:
3.2 mm
|
Colour:
White
|
Dual Use:
0
|
Int. tubing Ø:
4 ... 5 mm
|
Length:
21 mm
|
Manufacturer Article Number:
M 519-01
|
Material:
PP
|
Max. int. tubing Ø:
5 mm
|
Min. int. tubing Ø:
4 mm
|
Shape (Tubing connectors):
Straight
Zum Anschluss von Schläuchen auf b.safe Waste Caps.
Description:
HPLC starter kit I
|
Dual Use:
0
|
Manufacturer Article Number:
399200-PP
For the safe withdrawal of solvents. Screw caps, with freely movable insert, with PP fittings for capillaries and an air valve, with change indicator. For PFAS analysis of polyfluorinated chemicals according to DIN 38407-42/ DIN 38414-14.Complete set for up to 4 storage bottlesSuitable for all current HPLC systemsScope of supply:3 x Safety Cap I, GL 45, PFAS-Analytic1 x Safety Cap II, GL 45, PFAS-Analytic4 x air valve, PFAS-Analytic4 x change indicator5 x PP fitting 1.6 mm OD5 x PP fitting 2.3 mm OD5 x PP fitting 3.2 mm OD1 x PP blind plug4 x labelling field
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.
Variants from €12.99*
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.
Variants from €12.99*