Filter
Filter
Division:
1 %
|
Manufacturer Article Number:
0887
|
Max. measured value:
27 %
|
Measured range:
0 ... 27 %
|
Min. measured value:
0 %
|
Reference temperature:
15 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Ohne Thermometer.Ohne Thermometer.
Ground size:
NS10/19
|
Manufacturer Article Number:
43305
|
Material:
Boro 3.3
|
Nominal capacity:
5 ml
|
Reference temperature:
20 °C
|
Standard:
DIN ISO 3507
|
Type of construction (Pycnometers):
Acc. to Gay-Lussac
|
UNSPSC:
41103316
DIN ISO 3507, gay-lussac type. Including individual certificate. Adjusted. Reference temperature 20°C.With NS10/19 capillary stopper. Stopper top ground and polished. Inscription in highly contrasting blue enamel. The volume in cm³ is specified to a precision of 3 decimal places. Calibrated to contain. Every pycnometer is calibrated with its own stopper; hence, stoppers are not interchangeable. Each bottle and its stopper is marked with an unique matching identification number.
Division:
1 %
|
Manufacturer Article Number:
0891
|
Max. measured value:
47 %
|
Measured range:
0 ... 47 %
|
Min. measured value:
0 %
|
Reference temperature:
15 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Ohne Thermometer.Ohne Thermometer.
Ground size:
NS60/37
|
Manufacturer Article Number:
05660207
|
Material:
DURAN® tubing
|
NS:
60/37
|
Type:
Pycnometer head without conical shoulder bottle
|
UNSPSC:
41103316
Zur Bestimmung der Dichte (Rohdichte) von bituminösen Massen und Mineralstoffgemischen.
Variants from €59.40*
Division:
0.5 %
|
Manufacturer Article Number:
0884
|
Max. measured value:
35 %
|
Measured range:
0 ... 35 %
|
Min. measured value:
0 %
|
Reference temperature:
20 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Ohne Thermometer.Ohne Thermometer.
Description:
Wasser
|
Manufacturer Article Number:
242815
Die Dichtemessungen mit diesen Standards ist rückführbar auf die Primärmethode. Kompatibel mit Dichte- und Schallgeschwindigkeitsmessgeräten.ISO 17034-zertifizierte Referenzmaterialien. Erfüllen die Anforderungen von ISO 17025 und ISO 17034. Inhalt: 10 ml. Standzeit: 18 Monate.Die Dichtemessungen mit diesen Standards ist rückführbar auf die Primärmethode. Kompatibel mit Dichte- und Schallgeschwindigkeitsmessgeräten.ISO 17034-zertifizierte Referenzmaterialien. Erfüllen die Anforderungen von ISO 17025 und ISO 17034. Inhalt: 10 ml. Standzeit: 18 Monate.GefahrstoffdatenSDBLink
Division:
0.001 g/cm³
|
Length:
300 mm
|
Manufacturer Article Number:
3031013/04/3P
|
Max. measured value:
1.900 g/cm³
|
Measured range:
1.800 ... 1.900 g/cm³
|
Min. measured value:
1.800 g/cm³
|
Reference temperature:
20 °C
Dichte-Aräometer mit einer Fehlergrenze von ±0,001 g/cm3. In 4-kant Kunststoffhülse verpackt.
Variants from €213.97*
Division:
1 %
|
Manufacturer Article Number:
0897
|
Max. measured value:
0 %
|
Measured range:
30 ... 0 %
|
Min. measured value:
30 %
|
Reference temperature:
15 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Ohne Thermometer.Ohne Thermometer.
Length:
350 mm
|
Manufacturer Article Number:
0874
|
Reference temperature:
20 °C
|
Standard:
DIN 18123
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Bezugsthemperatur 20°C. Ohne Thermometer.Bezugsthemperatur 20°C. Ohne Thermometer.
Division:
0.001 g/cm³
|
Length:
300 mm
|
Manufacturer Article Number:
3031008/03/3P
|
Max. measured value:
1.400 g/cm³
|
Measured range:
1.300 ... 1.400 g/cm³
|
Min. measured value:
1.300 g/cm³
|
Reference temperature:
20 °C
|
UNSPSC:
41-11-30-24
Dichte-Aräometer mit einer Fehlergrenze von ±0,001 g/cm3. In 4-kant Kunststoffhülse verpackt.
Variants from €94.36*
Division:
0.001 g/cm³
|
Length:
90 mm
|
Manufacturer Article Number:
0908
|
Max. measured value:
1.030 g/cm³
|
Measured range:
1.000 ... 1.030 g/cm³
|
Min. measured value:
1.000 g/cm³
Bezugsthemperatur 20°C. Ohne Thermometer.Bezugsthemperatur 20°C. Ohne Thermometer.
Division:
1 %
|
Manufacturer Article Number:
0893
|
Max. measured value:
39 %
|
Measured range:
0 ... 39 %
|
Min. measured value:
0 %
|
Reference temperature:
15 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Ohne Thermometer.Ohne Thermometer.
Division:
0.001 g/cm³
|
Length:
300 mm
|
Manufacturer Article Number:
H801090
|
Max. measured value:
2.000 g/cm³
|
Measured range:
0.600 ... 2.000 g/cm³
|
Min. measured value:
0.600 g/cm³
|
Reference temperature:
20 °C
|
UNSPSC:
41-11-30-24
|
With thermometer:
No
Messbereichsspanne 0,100 g/cm³, Papierskala, schrotbeschwerter Körper, Aräometergenauigkeit: ±1 Skalenteilungswert, in transparenter Plastikhülse. Ablesung unten.LieferumfangKompletter Satz mit 14 Insturmenten im Etui.
Division:
0.001 g/cm³
|
Length:
300 mm
|
Manufacturer Article Number:
H801058
|
Max. measured value:
1.100 g/cm³
|
Measured range:
1.000 ... 1.100 g/cm³
|
Min. measured value:
1.000 g/cm³
|
Reference temperature:
20 °C
|
UNSPSC:
41-11-30-24
|
With thermometer:
No
Scale 0,100 g/cm³, paper scale, shot weighted body, hydrometer accuracy ±1 scale division, in transparent plastic case. Reading below.* Complete set with 14 insturments in stuffed case.
Division:
0.002 g/cm³
|
Length:
280 mm
|
Manufacturer Article Number:
0112
|
Max. measured value:
0.800 g/cm³
|
Measured range:
0.600 ... 0.800 g/cm³
|
Min. measured value:
0.600 g/cm³
|
Reference temperature:
20 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Shot poised. Without thermometer. Reference temperature: +20°C.Further models availlable on request.
Manufacturer Article Number:
023.01.005
|
Material:
Boro 3.3
|
Nominal capacity:
5 ml
|
Standard:
ISO 3507
For easy differentiation both the body and the stopper carries the same identification code number. Nominal volume and inscriptions are printed with blue enamel. Manufactured according to ISO 3507 standard.
Division:
0.001 g/cm³
|
Length:
160 mm
|
Manufacturer Article Number:
0001
|
Max. measured value:
0.660 g/cm³
|
Measured range:
0.600 ... 0.660 g/cm³
|
Min. measured value:
0.600 g/cm³
|
Reference temperature:
20 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
Shot poised. Without thermometer. Reference temperature: +20°C.Further models availlable on request.
Calibratable:
Yes
|
Division:
0.002 g/cm³
|
Length:
250 mm
|
Manufacturer Article Number:
0343
|
Max. measured value:
0.700 g/cm³
|
Measured range:
0.600 ... 0.700 g/cm³
|
Min. measured value:
0.600 g/cm³
|
Reference temperature:
20 °C
|
Standard:
DIN 12791
|
UNSPSC:
41-10-33-12
|
With thermometer:
No
DIN 12791 (and BS718). M100 series. Shot poised.Without thermometer. Reference temperature: +20 °C.Further models availlable on request.
Adjustment:
Yes
|
Manufacturer Article Number:
023.02.005
|
Material:
Boro 3.3
|
Nominal capacity:
5 ml
|
Standard:
ISO 3507
|
UNSPSC:
41103316
ISO 3507. Individually calibrated to contain (In) to 0.001ml. Net volume capacity is engraved on the body. Each bottle is calibrated together with its stopper. In order to differentiate easily, both the body and the stopper have the same code numbers printed on themselves.
Calibratable:
Yes
|
Division:
0.1 Vol.-%
|
Length:
330 mm
|
Manufacturer Article Number:
0750WG
|
Max. measured value:
5 Vol.-%
|
Measured range:
0 ... 5 Vol.-%
|
Min. measured value:
0 Vol.-%
|
Reference temperature:
20 °C
|
With thermometer:
Yes
According to E.E. 76/765. Class II, ethanol % vol. Suitable for official testing. Reference temperature: 20 °C. With thermometer.
Variants from €101.90*
Division:
0.1 °Bé
|
Length:
300 mm
|
Manufacturer Article Number:
0651WG
|
Reference temperature:
20 °C
|
UNSPSC:
41-10-33-12
|
With thermometer:
Yes
Dr. Ammer type.For testing boiler feedwater.With integral thermometer and temperature correction.Reference temperature +20°C.
Manufacturer Article Number:
0899
Battery acid tester 1.10 to 1.30.Boxed complete with glass tube, rubber bulb and hydrometer.
Division:
0.002 g/cm³
|
Length:
300 mm
|
Manufacturer Article Number:
3001220-R1
|
Material:
PC
|
Max. measured value:
1.220 g/cm³
|
Measured range:
1.000 ... 1.220 g/cm³
|
Min. measured value:
1.000 g/cm³
|
Reference temperature:
20 °C
Hydrometers made of high-quality plastics (polycarbonate).Breakage protected (no glass breakage)Fully made of resistant polycarbonate (PC)High transparency (like glass), easy-to-read scalesHigh precision and reproducibilitySuitable for applications in food, pharmaceutical and cosmetic industries as well as many othersMeasuring units: specific gravity, density, Oechsle, % mass, Brix, saturation, ° Baumé, etc.Made in GermanyWorks certificate available on request (option)Food safety according to HACCP
Colour filling:
Blue
|
Division:
0.001 g/cm³
|
Length:
350 mm
|
Manufacturer Article Number:
3051002S
|
Max. measured value:
0.800 g/cm³
|
Max. temperature:
35 °C
|
Measured range:
0.700 ... 0.800 g/cm³
|
Min. measured value:
0.700 g/cm³
|
Min. temperature:
0 °C
|
Reference temperature:
20 °C
|
Temperature:
0 ... 35 °C
|
With thermometer:
Yes
Density Hydrometers with an error limit of ±0.001 g/cm3. With thermometer 0 to 35°C in 1°C increments, blue filling, error limit ±2 °C.Further measuring ranges available on request.
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.
Variants from €12.99*
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.
Variants from €12.99*
Your watch lists