Filter
Filter
Macherey-Nagel GmbH & Co. KG
CHROMABOND® vacuum manifolds and accessories
Description:
Luer fittings for lid, female
|
Manufacturer Article Number:
730183.12
For simultaneous preparation of up to 12 or 24 samples,replacement parts and accessories for special applications.Vacuum manifold complete consists of: glass cabinet with lid and lid gasket, removable needles on lower side of lid, vacuum gauge, control valve, valves and caps, variable rack.
€45.20*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® C18 ec
Capacity mg:
100
|
Manufacturer Article Number:
730011
|
Volume ml:
1
Octadecyl modified silica phase for SPE, endcappedBase material silica, pore size 60 Å, particle size 45 µm for C18 ec, 100 µm for C18 ec f (for fast flow), specific surface 500 m²/g, pH stability 2 to 8. Octadecyl phases, endcapped, carbon content 14 % very non-polar, hydrophobic interactions with a wide variety of organic compounds. Advantageous for clean-up of samples with large structural variations (polarity differences).Recommended applications: non-polar compounds, aflatoxins, amphetamines, antibiotics, antiepileptics, barbiturates, caffeine, drugs, preservatives, fatty acids, nicotine, PAHs, pesticides, PCBs, heavy metals, vitamins. Very well suited for desalting of samples.BIGpacks: 4.003 446 / 4.003 450 / 4.003 452
€183.00*
Macherey-Nagel GmbH & Co. KG
CHROMAFIX® PS
Capacity mg:
380
|
Manufacturer Article Number:
731860
|
Phase:
PS-OH-
|
Size:
M
The innovative cation exchanger offers:mixed-mode SPE phase with distinct cation exchange and RP properties excellent enrichment of basic analytesmodern support polymer with optimised pore structure and large specific surfacegood reproducibility, reliable and cost-efficient analysesmore aggressive washing procedures for matrix removal possiblecleaner samples and protection of analytical HPLC and GC instrumentationquantificationof analytes from heavily contaminated sampleslower limits of detection also for critical matrices... the perfect fit for basic analytes in comination with CHROMABOND® HR-X
€203.00*
Macherey-Nagel GmbH & Co. KG
CHROMAFIX® HR-XC columns
Capacity mg:
155
|
Manufacturer Article Number:
731755
|
Size:
S
The innovative cation exchanger offers:mixed-mode SPE phase with distinct cation exchange and RP properties excellent enrichment of basic analytesmodern support polymer with optimised pore structure and large specific surfacegood reproducibility, reliable and cost-efficient analysesmore aggressive washing procedures for matrix removal possiblecleaner samples and protection of analytical HPLC and GC instrumentationquantificationof analytes from heavily contaminated sampleslower limits of detection also for critical matrices... the perfect fit for basic analytes in comination with CHROMABOND® HR-X
€222.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® SiOH
Capacity mg:
500
|
Manufacturer Article Number:
730073.250
|
Volume ml:
3
Unmodified silica phase for SPEUnmodified, weakly acidic silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, very polar, adsorbs humidity from air, for this reason it should be kept well closed and if necessary dried before use due to its high affinity for polar compounds it should not be conditioned with polar (e.g. methanol) or water-containing solvents.Recommended applications: aflatoxins, chloramphenicol, pesticides, steroids, vitamins.
€105.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® HR-P
Capacity mg:
500
|
Manufacturer Article Number:
730111G
|
Type:
HR-P*
|
UNSPSC:
23-15-18-16
|
Volume ml:
6
Polystyrene-divinylbenzene adsorbent resin for SPEBasic material: Highly porous polystyrene-divinylbenzene copolymer specific surface 1200 m2/g.Particle size 50-100 µm very high binding capacity, up to 30 % of adsorbent weight.Recommended application: aromatic compounds, phenols from water, nitroaromatics from water, pesticides from water, PAHs from oil*Glass column
€112.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® Florisil®
Capacity mg:
500
|
Manufacturer Article Number:
730081
|
Volume ml:
3
Magnesium silicate for SPEMatrix magnesium silicate (MgO to SiOH 15:85), high purity, particle size 150 to 250µm.Recommended application: organic tin compounds, aliphatic carboxylic acids, PCB, PAH.*Glass columns
€105.00*
Macherey-Nagel GmbH & Co. KG
Empty columns CHROMABOND®, PP
Dual Use:
0
|
Manufacturer Article Number:
730158
|
Volume ml:
70
Empty CHROMABOND® column (PP) for SPE, one PE-filter element is already inserted in the column.
€85.30*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® C18
Capacity mg:
500
|
Manufacturer Article Number:
730003.250
|
Volume ml:
3
Octadecyl modified silica phase for SPE, not endcappedBase material silica, pore size 60 Å, particle size 45 µm for C18, specific surface 500 m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14 % possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes.Recommended applications: non-polar compounds, pesticides.
€112.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® HR-X
Capacity mg:
200
|
Manufacturer Article Number:
730931
|
UNSPSC:
23-15-18-16
|
Volume ml:
3
Spherical, hydrophobic polystyrene-divinylbenzene resin for SPEHydrophobic polystyrene-divinylbenzene copolymer pH stability 1 to14. High-purity material with highest reproducibility and lowest blank values due to a novel manufacturing process, spherical particles 85mm; pore size 55 to 60Å. Very high surface 1000m²/g; capacity 390mg/g (caffeine in water). Excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimised pore structure.Recommended applications: pharmaceuticals/active ingredients from tablets, creams and water/waste water, drugs and pharmaceuticals from urine, blood, serum and plasma trace analysis of pesticides.Cartridges in further sizes and phases of the HR-X poduct range available on request.
€71.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® SB
Capacity mg:
100
|
Manufacturer Article Number:
730078
|
Volume ml:
1
Quaternary ammonium modified silica anion exchanger for SPE (SAX)Base material silica, pore size 60 Å, particle size 45 µm, specific surface 500 m²/g, pH stability 2 to 8. Silica modified with quaternary amine. Strongly basic anion exchanger (capacity ~ 0.3 meq/g). Not suited for very strong anions such as sulphonic acids, because these are difficult to elute.Recommended application: organic acids, caffeine, saccharin.BIGpacks: 4.003 487
€139.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® C6H5
Capacity mg:
500
|
Dual Use:
0
|
Manufacturer Article Number:
730084
|
UNSPSC:
41-11-57-11
|
Volume ml:
3
Phenyl modified silica phase for SPEBase material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8. Phenyl phase, carbon content 8%polarity similar to C8. In addition to hydrophobic interactions more selective adsorption is possible by Π-Π interactions due to the electron density of the phenyl ring.Recommended applications: aflatoxins, caffeine, phenols.
€166.00*
La-Pha-Pack GmbH
HPLC syringe filter ProFill, PTFE
Colour:
natural
|
Filter diam. mm:
25
|
Manufacturer Article Number:
25 16 0347
|
Membrane:
PTFE
|
Pore size µm:
0.45
Suitable for organic solutions, aggressive acids and alkalis, as well as cryogenic liquids.HydrophobPolypropylene housingEasy identification of the membrane type by colour codingFast filtration thanks to a filter area of 3.7 cm2Luer-Lock input and Luer-Slip output
€129.80*
Macherey-Nagel GmbH & Co. KG
CHROMAFIX® Alox N
Capacity mg:
850
|
Dual Use:
0
|
Manufacturer Article Number:
731844
|
Size:
S
Aluminium oxide, neutral, pH 7 ±0,5
€251.00*
Macherey-Nagel GmbH & Co. KG
CHROMAFIX® Dry
Capacity mg:
780
|
Manufacturer Article Number:
731852
|
Size:
S
|
UNSPSC:
23-15-18-16
Special phase for drying organic samplesBasic material: Sodium sulfate.Recommended application: removal of traces of water from organic solutions.
€125.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® NH2
Capacity mg:
100
|
Manufacturer Article Number:
730031
|
Volume ml:
1
Aminopropyl modified silica phase for SPEBase material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, aminopropyl phase, carbon content 3.5%, polar, weak anion exchanger.Recommended applications: trace elements, lipids.
€139.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® SA
Capacity mg:
500
|
Manufacturer Article Number:
730077.250
|
Volume ml:
3
Benzenesulphonic acid modified silica cation exchanger for SPE (SCX)Base material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, benzenesulphonic acid modified silica, strongly acidic cation exchanger (capacity ~ 0.5meq/g). Adsorbent with hydrophobic and Π-Π interactions (benzene ring). Ion exchange of organic compounds from aqueous matrix. Elution of interesting compounds with solvent systems, which compensate the ionic and nonpolar interactions, e.g. methanolic HCl.Recommended application: amino acids, amines, chlorophyll, PCB.
€139.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® SiOH-H2SO4/SA
Capacity mg:
500 / 500
|
Description:
Polypropylene columns
|
GHS:
GHS05
|
Manufacturer Article Number:
730085.250
|
Volume ml:
3
Combination phase for SPE analysis of PCBsH2SO4: H2SO4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds.SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification for removal of ionic and sulphur-containing compounds.Recommended application: extraction of PCBs from oil with reference to German industrial standard DIN 51527, part 1. This combination column is used together with a SiOH column.BIGpacks: 4.003 492Combination phase for SPE analysis of PCBsH2SO4: H2SO4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds.SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification for removal of ionic and sulphur-containing compounds.Recommended application: extraction of PCBs from oil with reference to German industrial standard DIN 51527, part 1. This combination column is used together with a SiOH column.BIGpacks: 4.003 492Hazardous Substance DataGHSSignal wordGefahrH-SatzH314P-SatzP260sh, P280sh, P303+P361+P353, P305+P351+P338, P310UNNR3260SDSLink
€249.00*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® PSA
Capacity mg:
500
|
Manufacturer Article Number:
730462
|
Volume ml:
3
Propylsulphonic acid modified silica cation exchanger for SPEBase material silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, propylsulphonic acid modified silica, very strong cation exchanger (capacity ~ 0.7meq/g), contrary to the SA phase no P-P interactions.Recommended applications: weak cations.
€209.00*
LLG Labware
LLG-Syringe filters NC, Nitrocellulose
Colour:
Transparent
|
Connetion inlet:
Luer-Lock female
|
Connetion outlet:
Luer-Slip male
|
Feature:
Hydrophilic
|
Manufacturer Article Number:
6285709
|
Material housing:
Acrylic
|
Membrane Ø:
25 mm
|
Pore size:
0.20 µm
|
Sterile:
Yes
|
UNSPSC:
41104922
LLG offers a line of syringe filters especially designed to provide efficient filtration of a broad variety of fluids, solvents, aqueous or inorganic solutions. Our syringe filters cover most applications in HPLC, pharmaceutical, environmental, biotechnology, as well as food and beverage testing laboratories.Housing injected in polypropylene and MABSSuperior pressure stability of the housingsSuitable for all syringes with Luer connectionHydrophilic membrane with low adsorption. For aqueous and aggressive organic solvent filtration. With Luer-Lock input and Luer-Slip output. Sterile products in individual hard blister packaging.For research and development only.
€134.80*
Macherey-Nagel GmbH & Co. KG
CHROMAFIL® MULTI 96 filter plates
Description:
Vacuum manifold for monoblocks, with reservoir tank, vacuum gaugeand control valve, required for filtration with 96-well filter plates
|
Manufacturer Article Number:
738630.M
96-well polypropylene plates for simultaneous filtration of 96 samplesAdvantages of this high-throughput system are:economical by saving time and solventuse of multi-channel pipettors facilitates liquid transfer stepsreadily adaptable to all common automated/robotic handling systems -minimised dead volume (£ 40µl)membrane materials correspond to the respective CHROMAFIL® syringe filters
€36.10*
La-Pha-Pack GmbH
HPLC syringe filter ProFill, RC / PA
Colour:
light green
|
Filter diam. mm:
25
|
Manufacturer Article Number:
25 16 0351
|
Membrane:
Nylon (PA)
|
Pore size µm:
0.45
|
UNSPSC:
41-10-49-22
For aqueous and organic media. The RC membrane is not suitable for aggressive acids and alkalis.HydrophilePolypropylene housingEasy identification of the membrane type by colour codingFast filtration thanks to a filter area of 3.7 cm2Luer-Lock input and Luer-Slip output
€129.80*
Macherey-Nagel GmbH & Co. KG
CHROMABOND® QuEChERS extraction buffer mixes / clean-up mixes
Composition:
4g MgSO4, 1g NaCl, 0.5g Na2H citrate1.5 H2O, 1g Na3 citrate, 2 H2O
|
Description:
Mix I Citrat-Extraction-Mix
|
Manufacturer Article Number:
730970
|
Volume ml:
15
QuEChERS method and pre-mixesWithin a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.Standard clean-up of food samples10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS.Extraction mixtures for sample preparation for determination of pesticides in food samples.MACHEREY-NAGEL offers a number of individually weighed and pre-mixed buffers and extraction mixtures, specially composed for different sample matrices.Mix I and Mix II are extraction mixtures, Mix III to Mix VI are clean-up mixtures.The food samples will be extracted with either Mix I or Mix II.Afterwards they will be purified with one of the following mixtures:Mix III (samples with low fat content; e.g. apples, strawberries),Mix IV (moderate content of chlorophyll and carotinoids; e. g. carrots, lettuce),Mix V (high content of chlorophyll and carotinoids; e. g. bell peppers, spinach),Mix VI (high fat content; e. g. avocados).Every mix is prepacked in a 15 ml centrifuge tube. Pack of 50 pieces.QuEChERS method and pre-mixesWithin a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.Standard clean-up of food samples10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS.Extraction mixtures for sample preparation for determination of pesticides in food samples.MACHEREY-NAGEL offers a number of individually weighed and pre-mixed buffers and extraction mixtures, specially composed for different sample matrices.Mix I and Mix II are extraction mixtures, Mix III to Mix VI are clean-up mixtures.The food samples will be extracted with either Mix I or Mix II.Afterwards they will be purified with one of the following mixtures:Mix III (samples with low fat content; e.g. apples, strawberries),Mix IV (moderate content of chlorophyll and carotinoids; e. g. carrots, lettuce),Mix V (high content of chlorophyll and carotinoids; e. g. bell peppers, spinach),Mix VI (high fat content; e. g. avocados).Every mix is prepacked in a 15 ml centrifuge tube. Pack of 50 pieces.Hazardous Substance DataSDSLink
€108.00*
LLG Labware
LLG-Syringe filters PE, Polyethylene
Colour:
Transparent
|
Connetion inlet:
Luer-Lock female
|
Connetion outlet:
Luer-Slip male
|
Manufacturer Article Number:
9055541
|
Material housing:
PP
|
Material membrane:
PE
|
Membrane Ø:
25 mm
|
Pore size:
0.2 µm
|
Sterile:
No
|
UNSPSC:
41104922
LLG offers a line of syringe filters especially designed to provide efficient filtration of a broad variety of fluids, solvents, aqueous or inorganic solutions. Our syringe filters cover most applications in HPLC, pharmaceutical, environmental, biotechnology, as well as food and beverage testing laboratories.Housing injected in polypropylene and MABSSuperior pressure stability of the housingsSuitable for all syringes with Luer connectionUniversal filter membrane for all analytical requirements. For aqueous and aggressive organic solvent filtration.Wide application in sample preparation, and ion chromatography. With Luer-Lock input and Luer-Slip output.
€118.00*
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.*According to DIN standard
€12.32*
Promotion
Evaporating basins, porcelain, shallow form
Glazed inside and outside except for rim.*According to DIN standard
€12.32*
Your watch lists