Harvard Apparatus (BTX)

Electrofusion and electroporation system ECM® 2001+, Generator | Description: ECM® 2001+ Generator

Article number: 4687940

€30,260.00*

Packaging unit: 1 piece

on order

Product information "Electrofusion and electroporation system ECM® 2001+, Generator | Description: ECM® 2001+ Generator"
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.

  • Large, easy-to-use touchscreen interface

  • Preset protocols for common hybridoma, embryo manipulation, and nuclear transfer applications

  • Separate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigation

  • Quick start menus for fast access to the most frequently used electrofusion and electroporation parameters

  • User-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol step

  • Storage of up to 1000 user-defined protocols

Scope of supply: Generator ECM® 2001+, high voltage output cable 1.5 m, adapter set

Square wave (DC)
Voltage LV mode:
5 ... 500 V
Voltage HV mode:
505 ... 3000 V
Multiple pulse:
1 ... 100 pulses per sample
Pulse length LV mode:
10 µs ... 999 ms
Pulse length HV mode:
10 µs ... 600 µs
Pulse interval:
0.1 ... 10 s
Sine wave (AC)
Voltage:
5 ... 75 V
Frequency:
0.2 ... 2 MHz
Pulse length:
0 ... 99 s
Charging time:
7 s
Depth: 330 mm
Description: ECM® 2001+ Generator
Dimensions (WxDxH): 305 x 330 x 330 mm
Height: 330 mm
Max. permitted ambient temperature: 40 °C
Max. relative humidity rate: 80 %
Min. permitted ambient temperature: 4 °C
Permitted ambient conditions: 4 ... 40 °C , 80 % RH
Power supply: 100 ... 240 V, 50/60 Hz
Type of auxiliary energy: Mains connection
Weight: 10 kg
Width: 305 mm

Other customers also bought

Electrofusion and electroporation system ECM® 2001+, Embryo manipulation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.Large, easy-to-use touchscreen interfacePreset protocols for common hybridoma, embryo manipulation, and nuclear transfer applicationsSeparate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigationQuick start menus for fast access to the most frequently used electrofusion and electroporation parametersUser-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol stepStorage of up to 1000 user-defined protocolsThe 0.5 and 1.0 mm microslides produce a divergent energy field ideal for efficient embryo fusion. The 3.2 mm microslide provides a homogeneous energy field for high fusion rates of hybridoma cells.Scope of supply: Generator ECM® 2001+, microslides with round wire electrode (0.5 mm / 1.0 mm), microslide with rectangular wire electrode (3.2 mm), micrograbber adapter cablesSquare wave (DC)Voltage LV mode:5 ... 500 VVoltage HV mode:505 ... 3000 VMultiple pulse:1 ... 100 pulses per samplePulse length LV mode:10 µs ... 999 msPulse length HV mode:10 µs ... 600 µsPulse interval:0.1 ... 10 sSine wave (AC)Voltage:5 ... 75 VFrequency:0.2 ... 2 MHzPulse length:0 ... 99 sCharging time:7 s
€31,710.00*
Electrofusion and electroporation system ECM® 2001+, Cell fusion system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.Large, easy-to-use touchscreen interfacePreset protocols for common hybridoma, embryo manipulation, and nuclear transfer applicationsSeparate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigationQuick start menus for fast access to the most frequently used electrofusion and electroporation parametersUser-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol stepStorage of up to 1000 user-defined protocolsThe supplied safety stand connects to the generator to safely deliver high voltage electrical pulses to cuvettes.The flat electrode generates a divergent field for cell fusion.Scope of supply: Generator ECM® 2001+, microslide (0.5 mm / 3.2 mm), Meander fusion chamber, flat electrode, electrode adapter, connection cable, safety stand, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rackSquare wave (DC)Voltage LV mode:5 ... 500 VVoltage HV mode:505 ... 3000 VMultiple pulse:1 ... 100 pulses per samplePulse length LV mode:10 µs ... 999 msPulse length HV mode:10 µs ... 600 µsPulse interval:0.1 ... 10 sSine wave (AC)Voltage:5 ... 75 VFrequency:0.2 ... 2 MHzPulse length:0 ... 99 sCharging time:7 s
€34,200.00*
Electrofusion and electroporation system ECM® 2001+, Hybridoma production system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.Large, easy-to-use touchscreen interfacePreset protocols for common hybridoma, embryo manipulation, and nuclear transfer applicationsSeparate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigationQuick start menus for fast access to the most frequently used electrofusion and electroporation parametersUser-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol stepStorage of up to 1000 user-defined protocolsThe coaxial chambers have identical electrical characteristics to allow direct scale-up to production once the pulse parameters have been optimised. Coaxial optimisation chamber with transparent bottom allows visualisation of the cell alignment by inverted or regular microscope.Scope of supply: Generator ECM® 2001+, coaxial optimisation chamber (2 ml), coaxial production chamber (9 ml), adapter set, cytofusion medium C (500 ml)Square wave (DC)Voltage LV mode:5 ... 500 VVoltage HV mode:505 ... 3000 VMultiple pulse:1 ... 100 pulses per samplePulse length LV mode:10 µs ... 999 msPulse length HV mode:10 µs ... 600 µsPulse interval:0.1 ... 10 sSine wave (AC)Voltage:5 ... 75 VFrequency:0.2 ... 2 MHzPulse length:0 ... 99 sCharging time:7 s
€31,280.00*
Electrofusion and electroporation system ECM® 2001+, Electroporation system
Multifunctional system for fast, efficient cell fusion in hybridoma production, hybrid cell formation, and nuclear transfer, as well as square wave electroporation for transfection of genes and other molecules into mammalian cell lines.Large, easy-to-use touchscreen interfacePreset protocols for common hybridoma, embryo manipulation, and nuclear transfer applicationsSeparate electrofusion and electroporation function menus for optimised protocol programming, data organisation, and navigationQuick start menus for fast access to the most frequently used electrofusion and electroporation parametersUser-defined electrofusion protocols: combination of up to 19 AC protocol steps and 1 DC protocol stepStorage of up to 1000 user-defined protocolsThe supplied safety stand connects to the generator to safely deliver high voltage electrical pulses to cuvettes.Scope of supply: Generator ECM® 2001+, safety stand, electroporation cuvettes 1 mm / 2 mm / 4 mm (10 each), cuvette rackSquare wave (DC)Voltage LV mode:5 ... 500 VVoltage HV mode:505 ... 3000 VMultiple pulse:1 ... 100 pulses per samplePulse length LV mode:10 µs ... 999 msPulse length HV mode:10 µs ... 600 µsPulse interval:0.1 ... 10 sSine wave (AC)Voltage:5 ... 75 VFrequency:0.2 ... 2 MHzPulse length:0 ... 99 sCharging time:7 s
€31,010.00*

Accessories

Electroporation cuvettes Plus
BTX Cuvettes Plus are designed for use in electroporation and electrofusion of bacteria, yeast, insect, plant and mammalian cells. Each sterilized Cuvettes Plus package includes a disposable cuvette and a transfer pipette, which is used for removal of the sample after electroporation. The cuvettes are molded with embedded polished aluminum electrodes, and gamma irradiated for guaranteed sterility.Three electrode gap sizes are available:1mm for bacteria and yeast2mm for all cell types4mm for mammalian cellsBTX cuvette Plus can obtain high field strengths up to 25.0 kV/cm. Round caps are leak resistant and allow for quick and easy removal. For research use only. Can be used with electroporation systems from different manufacturers (not suitable for units from Eppendorf).
€81.70*